2026-508 Calibration CertificatesDisclosure log response · North Wales Police
2026-508 Calibration Certificates.pdf
Read it at North Wales Police's website
- Published
- 9 Jun 2026
- Published by
- North Wales Police
- Source
- North Wales Police's website
- Recorded by PoliceFOI
- 2 Sept 2026
In full, as North Wales Police published it
We show a record in full only where its publisher's terms allow it. Most police forces in England and Wales publish under the same publication scheme terms: anyone may reproduce a force's own material free of charge if it is accurate and not misleading and the source and copyright are acknowledged, but not for any commercial purpose. PoliceFOI is published by a company, so we treat our use as commercial, and for those forces we show each record's title and summary, with a link to the original, until the force agrees to more. A few forces' terms are stricter still. None of these terms covers material owned by someone else, or a force's logo, so we link to such material rather than copy it.
Files
- File PDF, 723 KB
The original
The text of this file
Uned Rhyddid Gwybodaeth / Freedom of Information Unit
Pencadlys yr Heddlu,
Glan-y-Don, Bae Colwyn LL29 8AW
www.heddlugogleddcymru.police.ukPolice Headquarters,
Glan-y-Don, Colwyn Bay LL29 8AW
www.northwales.police.ukResponse Date:09/06/2026
2026/508 - Calibration Certificates
In response to your recent request for information regarding;
Please can you provide me with the last 5 Calibration Certificates for the speed
camera located B5129 Pentre, FlintshirePlease find attached.
THIS INFORMATION HAS BEEN PROVIDED IN RESPONSE TO A REQUEST
UNDER THE FREEDOM OF INFORMATION ACT 2000, AND IS CORRECT AS AT08/06/2026
All parts and components used in Device Serial Number
Signed by: Derek Penn
Director of Operations
Calibrating Engineer: Simon Kennington
Site Code: 779
Site Name: B5129 Pentre
Project ID: P4544M (P4566SR)
Device Location: 53.2014, -3.01339
Site Calibration Start Date:
Radar Factory Calibration Date:
Valid Until*:
* Site Calibration Valid until up to one year from Site Calibration Start Date, or three years from Radar Factory
Calibration Date, whichever is sooner.
SRCRT1127 P4544M (P4566SR)
Certificate of Calibration
VECTOR SR
Speed and/or Traffic Signals Enforcement Device
“I confirm that the VECTOR SR Enforcement System for Speed and/or Traffic Signals described below has been
calibrated to the documented parameters as recorded below using measurement devices calibrated to National
Standards in accordance with the Home Office Type Approval for the VECTOR SR device.
JE810100720-0187
including any replaced are identical to those used in the device as Type-Approved”
06/01/2026
01/12/2025
05/01/2027Laser Measure Calibration Date: 10/04/2025 Serial Number: 2444070518
Radar Alignment Tool Calibration Date: 06/01/2026 Serial Number: 4910474
250 249.9 / 249.9
300 300.0 / 300.0
Calibration Tools
Measuring Tape Calibration Date: 06/01/2026 Serial Number: SK001
50 50.1 / 50.1
100 100.2 / 100.2
200 199.8 / 199.8
10 10.1 / 10.1
24.085 24.087
24.125 24.127
24.165 24.167
24.205 24.207
Radar Speed Test
Simulated Speed (km/h) Measured Speed (km/h) Approach / Recede
Radar Factory Calibration Date 01/12/2025
Specified Radar Frequency (GHz) Measured Radar Frequency (GHz)
24.045 24.047
FST3 Radar Serial Number 590-113/63495
VECTOR Serial Number SB160819-0109
Device Distance to Notional Stop Line (m) 30
Device Height (m) 5.32
Device Offset (m) 3.56
Site Calibrated by Simon Kennington
Radar Factory Calibration Report
Device Serial Number JE810100720-0187
SRCRT1127 P4544M (P4566SR)
Date
Site Calibration Start Date 06/01/2026
Location
Site Name 779 - B5129 Pentre
Device Location 53.2014, -3.01339
Asset Calibration
All parts and components used in Device Serial Number
Signed by: Derek Penn
Director of Operations
Calibrating Engineer: Stephen Pigden
Annual Inspection Engineer: Simon Kennington
Site Code: 779
Site Name: B5129 Pentre
Project ID: P4544M (P4566SR)
Device Location: 53.2014, -3.01348
Initial Site Calibration Start Date:
Annual Inspection Date:
Radar Factory Calibration Date:
Valid Until*:
Jenoptik UK Ltd.,Ten Watchmoor Park, Riverside Way, Camberley Surrey GU15 3YL UK
* Site Calibration Valid until up to one year from Site Calibration / Calibration Inspection Date, or three years from
Radar Factory Calibration Date, whichever is sooner.
20/10/2025
SRCRT723 P4544M (P4566SR)
Certificate of Calibration
VECTOR SR
Speed and/or Traffic Signals Enforcement Device
“I confirm that the VECTOR SR Enforcement System for Speed and/or Traffic Signals described below has been
calibrated to the documented parameters as recorded below using measurement devices calibrated to National
Standards in accordance with the Home Office Type Approval for the VECTOR SR device.
JE810100720-0187
including any replaced are identical to those used in the device as Type-Approved”
30/10/2023
21/10/2024
19/01/2023Laser Measure Calibration Date: 21/06/2024 Serial Number: 1052459636
Annual Inspection Tools
Vbox Calibration Date: 11/04/2024 Serial Number: 079687
Laser Measure Calibration Date: 08/03/2023 Serial Number: 332320238
Radar Alignment Tool Calibration Date: 30/10/2023 Serial Number: W465-000/60015
300 300.0 / 300.0
Initial Calibration Tools
Measuring Tape Calibration Date: 30/10/2023 Serial Number: SP-VYS-01
100 100.2 / 100.2
200 199.8 / 199.8
250 249.9 / 249.9
50 50.1 / 50.1
24.125 24.127
24.165 24.167
24.205 24.207
Radar Speed Test
Simulated Speed (km/h) Measured Speed (km/h) Approach / Recede
10 10.1 / 10.1
Specified Radar Frequency (GHz) Measured Radar Frequency (GHz)
24.045 24.047
24.085 24.088
Radar Factory Calibration Date 19/01/2023
Device Height (m) 5.41
Device Offset (m) 3.555
Site Calibrated by Stephen Pigden
Site Inspected by Simon Kennington
Radar Factory Calibration Report
FST3 Radar Serial Number 590-113/63215
Device Distance to Notional Stop Line (m) 30
Annual Inspection Date 21/10/2024
Location
Site Name 779 - B5129 Pentre
Device Location 53.2014, -3.01348
Asset Calibration
Device Serial Number JE810100720-0187
VECTOR Serial Number SB160819-0109
SRCRT723 P4544M (P4566SR)
Date
Initial Site Calibration Start Date 30/10/2023
All parts and components used in Device Serial Number
Signed by: Michael Kirsch
Product Design Director
Calibrating Engineer: Andrew Flanagan
Annual Inspection Engineer: Andrew Flanagan
Site Code: 705
Site Name: B5129 Pentre
Project ID: P4544M (P4566SR)
Device Location: 53.2014, -3.01347
Initial Site Calibration Start Date:
Annual Inspection Date:
Radar Factory Calibration Date:
Valid Until*:
Jenoptik Traffic Solutions UK Ltd.,Ten Watchmoor Park, Riverside Way, Camberley Surrey GU15 3YL UK
06/02/2023
* Site Calibration Valid until up to one year from Site Calibration / Calibration Inspection Date, or three years from
Radar Factory Calibration Date, whichever is sooner.
P4544M (P4566SR)SRCRT182
Certificate of Calibration
VECTOR SR
Speed and/or Traffic Signals Enforcement Device
“I confirm that the VECTOR SR Enforcement System for Speed and/or Traffic Signals described below has been
calibrated to the documented parameters as recorded below using measurement devices calibrated to National
Standards in accordance with the Home Office Type Approval for the VECTOR SR device.
including any replaced are identical to those used in the device as Type-Approved”
JE810100720-0187
04/11/2020
03/11/2020
07/02/202207/02/2022Annual Inspection Date
Site Inspected by Andrew Flanagan
SRCRT182 P4544M (P4566SR)
Date
Initial Site Calibration Start Date 04/11/2020
Location
Site Name 705 - B5129 Pentre
Device Location 53.2014, -3.01347
Asset Calibration
Device Serial Number JE810100720-0187
VECTOR Serial Number SB160819-0109
Serial Number:
Initial Calibration Tools
Site Calibrated by Andrew Flanagan
590-113/65421
Specified Radar Frequency (GHz) Measured Radar Frequency (GHz)
24.205 24.207
Radar Factory Calibration Date
24.125 24.127
04/11/2020 AF002Measuring Tape Calibration Date:
Radar Alignment Tool Calibration Date: 04/11/2020 Serial Number: W465-000/60028
Laser Measure Calibration Date: 27/02/2020 Serial Number: 1084510494
FST3 Radar Serial Number
03/11/2020
24.045 24.046
24.085 24.088
Device Distance to Notional Stop Line (m)
Device Height (m)
28
5.28
Radar Factory Calibration Report
1.75Device Offset (m)
300 300.0 / 300.0
10 10.1 / 10.1
50 50.1 / 50.1
100 100.2 / 100.2
24.165 24.167
200 199.8 / 199.8
250 249.9 / 249.9
Radar Speed Test
Simulated Speed (km/h) Measured Speed (km/h) Approach / Recede
Annual Inspection Tools
Vbox Calibration Date: 08/05/2021 Serial Number: 085101
Laser Measure Calibration Date: 11/06/2021 Serial Number: 1084510494
All parts and components used in Device Serial Number
Signed by: Michael Kirsch
Product Design Director
Calibrating Engineer: Andrew Flanagan
Site Code: 705
Site Name: B5129 Pentre
Project ID: P4544M (P4566SR)
Device Location: 53.2014, -3.01348
Site Calibration Start Date:
Radar Factory Calibration Date:
Valid Until*:
Jenoptik UK Ltd.,Ten Watchmoor Park, Riverside Way, Camberley Surrey GU15 3YL UK
* Site Calibration Valid until up to one year from Site Calibration Start Date, or three years from Radar Factory
Calibration Date, whichever is sooner.
SRCRT284 P4544M (P4566SR)
Certificate of Calibration
VECTOR SR
Speed and/or Traffic Signals Enforcement Device
“I confirm that the VECTOR SR Enforcement System for Speed and/or Traffic Signals described below has been
calibrated to the documented parameters as recorded below using measurement devices calibrated to National
Standards in accordance with the Home Office Type Approval for the VECTOR SR device.
JE810100720-0187
including any replaced are identical to those used in the device as Type-Approved”
31/01/2023
19/01/2023
30/01/2024Device Serial Number JE810100720-0187
SRCRT284 P4544M (P4566SR)
Date
Site Calibration Start Date 31/01/2023
Location
Site Name 705 - B5129 Pentre
Device Location 53.2014, -3.01348
Asset Calibration
FST3 Radar Serial Number 590-113/63215
VECTOR Serial Number SB160819-0109
Device Distance to Notional Stop Line (m) 28
Device Height (m) 5.28
Device Offset (m) 3.485
Site Calibrated by Andrew Flanagan
Radar Factory Calibration Report
Radar Factory Calibration Date 19/01/2023
Specified Radar Frequency (GHz) Measured Radar Frequency (GHz)
24.045 24.047
10 10.1 / 10.1
24.085 24.088
24.125 24.127
24.165 24.167
24.205 24.207
Radar Speed Test
Simulated Speed (km/h) Measured Speed (km/h) Approach / Recede
50 50.1 / 50.1
100 100.2 / 100.2
200 199.8 / 199.8
Measuring Tape Calibration Date: 31/01/2023 Serial Number: AF003
250 249.9 / 249.9
300 300.0 / 300.0
Calibration Tools
Radar Alignment Tool Calibration Date: 31/01/2023 Serial Number: 4910474
Laser Measure Calibration Date: 23/03/2022 Serial Number: 322750057
All parts and components used in Device Serial Number
Signed by: Derek Penn
Director of Operations
Calibrating Engineer: Stephen Pigden
Site Code: 779
Site Name: B5129 Pentre
Project ID: P4544M (P4566SR)
Device Location: 53.2014, -3.01348
Site Calibration Start Date:
Radar Factory Calibration Date:
Valid Until*:
Jenoptik UK Ltd.,Ten Watchmoor Park, Riverside Way, Camberley Surrey GU15 3YL UK
* Site Calibration Valid until up to one year from Site Calibration Start Date, or three years from Radar Factory
Calibration Date, whichever is sooner.
SRCRT441 P4544M (P4566SR)
Certificate of Calibration
VECTOR SR
Speed and/or Traffic Signals Enforcement Device
“I confirm that the VECTOR SR Enforcement System for Speed and/or Traffic Signals described below has been
calibrated to the documented parameters as recorded below using measurement devices calibrated to National
Standards in accordance with the Home Office Type Approval for the VECTOR SR device.
JE810100720-0187
including any replaced are identical to those used in the device as Type-Approved”
30/10/2023
19/01/2023
29/10/2024Device Serial Number JE810100720-0187
SRCRT441 P4544M (P4566SR)
Date
Site Calibration Start Date 30/10/2023
Location
Site Name 779 - B5129 Pentre
Device Location 53.2014, -3.01348
Asset Calibration
FST3 Radar Serial Number 590-113/63215
VECTOR Serial Number SB160819-0109
Device Distance to Notional Stop Line (m) 30
Device Height (m) 5.41
Device Offset (m) 3.555
Site Calibrated by Stephen Pigden
Radar Factory Calibration Report
Radar Factory Calibration Date 19/01/2023
Specified Radar Frequency (GHz) Measured Radar Frequency (GHz)
24.045 24.047
10 10.1 / 10.1
24.085 24.088
24.125 24.127
24.165 24.167
24.205 24.207
Radar Speed Test
Simulated Speed (km/h) Measured Speed (km/h) Approach / Recede
50 50.1 / 50.1
100 100.2 / 100.2
200 199.8 / 199.8
Measuring Tape Calibration Date: 30/10/2023 Serial Number: SP-VYS-01
250 249.9 / 249.9
300 300.0 / 300.0
Calibration Tools
Radar Alignment Tool Calibration Date: 30/10/2023 Serial Number: W465-000/60015
Laser Measure Calibration Date: 08/03/2023 Serial Number: 332320238
© North Wales Police. Reproduced for non-commercial purposes from https://www.northwales.police.uk/SysSiteAssets/foi-media/north-wales/disclosure-2026/2026-508--calibration-certificates.pdf under North Wales Police's publication scheme terms, which allow free reproduction if accurate and not misleading, with the source and copyright acknowledged. The text only, as read from the published documents; material owned by others is not covered. Collected on 2 September 2026; North Wales Police may have changed or withdrawn it since.
If this text names you or you own part of it, ask us to take the full text down: it is hidden as soon as you send the form, and the title and summary stay.
Related releases
- 2024-1160 Glass attacks Disclosure log response · North Wales Police · 1 Jan 2027
- 2026 -901 Britannia Bridge Crossing Disclosure log response · North Wales Police · 22 Sept 2026
- 2026-967 Crimes committed at pharmacies Disclosure log response · North Wales Police · 22 Sept 2026
- 2026-936 Police non-fatal strangulation and suffocation offences Disclosure log response · North Wales Police · 21 Sept 2026
- 2026- 940 theft and burglary at construction sites Disclosure log response · North Wales Police · 21 Sept 2026
Ask us to remove a name from this page (free) · Report a mistake